DP Diagnostics

PM is the exclusive distributor for DP Diagnostics.

Accuracy
± 0.5% of Reading 1
Repeatability
± 0.1%
Turndown
10:1 or higher
Diagnostic Sensitivity
≤ 2%
Beta Ratios
.45, .50, .55, .60, .65, .70, .75
Diameter Range
3” to 14” 2
Pressure Rating
150# - 2500# Class Flanges 3
Meter Installation Requirements
0 - 5 diameters upstream depending on the type of disturbance.
Codes and Standards
The meter will be manufactured in accordance with customer requirements. (eg. B31.1, B31.3…)
Materials of Construction
304 & 316, Duplex S31803/S32205, SuperDuplex S32750/S32760, 6% Moly S31254, Carbon Steels 4

1 Each Meter will be calibrated in liquid or gas across the full Reynolds number range applicable to the customer’s application.
2 Other diameters available upon request. 3 RTJ, Slip-on, Hub connections also available. 4 Other materials upon request.